RECORD # 3 : DRILLING CONNECTIONS

WITS Record ID 3 Logical Record Type 153 Auto/Manual AUTOMATIC
Trigger [EVENT] Transmit when first back on bottom following a drilling connection
Data Source Data acquired from first off-bottom to back on-bottom

ItemDescriptionLong MnemonicShort Mnemonic TypeLengthMetric Units FPS Units
1Well IdentifierWELLIDWIDA16--------
2Sidetrack/Hole Sect No.STKNUMSKNOS2--------
3Record Identifier RECIDRIDS2--------
4Sequence Identifier SEQIDSQIDL4--------
5Date DATE DATEL4--------
6Time TIME TIMEL4 ---- ----
7Activity Code ACTCODACTCS2--------
8Depth Connection (meas)DEPTCONMDCNMF4MF
9Depth Connection (vert)DEPTCONVDCNVF4MF
10Depth Hole (meas)DEPTMEASDMEAF4MF
11Depth Hole (vert)DEPTVERTDVERF4MF
12Elapsed Time Bottom-SlipsETIMEBTSETBSS2SECSEC
13Elapsed Time In-SlipsETIMESLPETSLS2SECSEC
14Elapsed Time Slips-Bottom ETIMESTBETSBS2SECSEC
15Elapsed Time Pumps-OffETIMEPOFETPOS2SECSEC
16Running Speed - up (max)RSUXRSUXF4M/SFPM
17Running Speed - down (max)RSDXRSDXF4M/SFPM
18Hookload (max)HKLXHKLXF4 KDNKLB
19String Weight (rot,avg)STRGWTSTWTF4KDNKLB
20Torque - Make Up (max)TORQMUXTQMXF4KNM KFLB
21Torque - Breakout (max)TORQBOXTQBXF4KNMKFLB
22< SPARE 1 >SPARE1SPR1F4--------
23< SPARE 2 >SPARE2SPR2F4--------
24< SPARE 3 >SPARE3SPR3F4--------
25< SPARE 4 >SPARE4SPR4F4--------
26< SPARE 5 >SPARE5SPR5F4--------